Carrier infinity is one of the most dependable air conditioning units you can have.
But like any other air con, a problem may occasionally arise that prevents the AC from cooling efficiently, leaving you exposed to scorching heat when summer comes around.
Luckily, the displayed fault codes can give you a clue about the exact malfunctioning part to help you resolve the issue.
And the good thing is that a great deal of the problems have uncomplicated solutions.
Use this carrier infinity fault codes troubleshooting guide to fix your unit and beat the blistering heat the peak of summers bring.
It’s worth mentioning that we will also look at some of the most common Carrier thermostat error codes and even the commonest carrier infinity furnace fault codes.
Carrier infinity fault codes – guide to troubleshooting various carrier infinity error codes including carrier infinity thermostat fault codes
Use this detailed carrier infinity troubleshooting guide to service your product….
Carrier Infinity fault codes are used to diagnose and troubleshoot issues with Carrier Infinity series HVAC systems. These fault codes provide valuable information about the system’s malfunctions and can help technicians pinpoint the problem more efficiently. Here’s a general guide on how to diagnose Carrier Infinity fault codes:
Carrier infinity fault codes -Outdoor Unit Generated carrier infinity error codes (assorted models)
Flash Code on Outdoor Board: 51 for 38TDB, YDB 598B, 698B models and 32 for 24ANA, 25HNA 187A, 180A, 286A, 288A
Fault description: Low Pressure Switch trip
Potential cause and action: Switch is monitored at all
Flash Code on Outdoor Board: 52 for 38TDB, YDB 598B, 698B models and 31 for 24ANA, 25HNA 187A, 180A, 286A, 288A
Fault description: High Pressure Switch trip
Potential cause and action: High-pressure switch trip. Re-Check refrigerant charge and the coils for air flow restrictions.
Flash Code on Outdoor Board: 3 for 38TDB, YDB 598B, 698B models and 53 for 24ANA, 25HNA 187A, 180A, 286A, 288A
Fault description: Outside Temp Sensor issue
Potential cause and action: Ohm out sensor and check wiring. May also indicate lost communication with the outdoor unit.
Flash Code on Outdoor Board: 4 for 38TDB, YDB 598B, 698B models and 55 for 24ANA, 25HNA 187A, 180A, 286A, 288A
Fault description: Coil Temp Sensor issue
Potential cause and action: Ohm out sensor fault and check wiring.
Flash Code on Outdoor Board: 34 for 38TDB, YDB 598B, 698B models and 56 for 24ANA, 25HNA 187A, 180A, 286A, 288A
Fault description: Thermistor Range Error
Potential cause and action: Improper relationship between coil sensor and outdoor sensor. Ensure the outdoor sensor is placed outside cabinet. Ohm out sensors and check wiring.
Flash Code on Outdoor Board: 6 for 38TDB, YDB 598B, 698B models and 73 for 24ANA, 25HNA 187A, 180A, 286A, 288A
Fault description: Contactor shorted
Potential cause and action: Voltage sensed at run capacitor when no call for compressor operation. Might be caused by stuck contactor, if contactor has been manually pushed in (by technician)
Flash Code on Outdoor Board: 71 for 24ANA, 25HNA 187A, 180A, 286A, 288A and 6 for 38TDB, YDB 598B, 698B models
Fault description: Low Capacity Thermal Cutout
Potential cause and action: Voltage present on run capacitor in low speed then disappears. Likely reasons are internal compressor over-load trip or the start relay failing to release. Check these.
Flash Code on Outdoor Board: 72 for 24ANA, 25HNA 187A, 180A, 286A, 288A and 6 for 38TDB, YDB 598B, 698B models
Fault description: High Capacity Thermal Cutout
Potential cause and action: Voltage present on run capacitor in hi speed then disappears. Likely reasons are internal compressor over-load trip or the start relay failing to release. Check them.
Flash Code on Outdoor Board: 47 for 24ANA, 25HNA 187A, 180A, 286A, 288A and 6 for 38TDB, YDB 598B, 698B models
Fault description: No high voltage to outdoor unit.
Potential cause and action: Voltage not present on run capacitor when compressor should be starting. Potential triggers: disconnect removed or perhaps high-voltage not connected. Check.
Flash Code on Outdoor Board: 81 for 24ANA, 25HNA 187A, 180A, 286A, 288A and 6 for 38TDB, YDB 598B, 698B models
Fault description: Low Capacity thermal Lockout
Potential cause and action: Control detects thermal cutout in 3 consecutive low stage. On cycles
Flash Code on Outdoor Board: 82 for 24ANA, 25HNA 187A, 180A, 286A, 288A and 6 for 38TDB, YDB 598B, 698B models
Fault description: Hi Capacity thermal Lockout
Potential cause and action: Thermal cutout occurs in three consecutive high cycles in new platform outdoor units. a combination of three(3) hi & low cycles will bring this event on older platform 2 stage models.
Carrier infinity fault codes – Fan Coil Generated carrier infinity codes (commonest)
Flash error code | Fault description
|
16
|
System Commu-nications fault
|
25 | Invalid Model/Motor Selection |
26 | Invalid Heater Size |
27 | Invalid Outdoor Unit Size |
36 | Heater output not sensed when energized |
37 | Heater output sensed On when not energized |
41 | Blower Motor Fault |
44 | Motor communication Fault |
46 | Brown Out Condition |
Carrier thermostat error codes
Error code 16
Fault description: System Commu-nications Failure
Potential cause and action: Communication with the user interface lost. Inspect wiring to User Interface and the indoor & outdoor units
Error code 25
Fault description: Invalid Model Plug
Potential cause and action: Control is not detecting a model plug/ detects an invalid one. Unit won’t operate without the correct model plug.
Error code 31
Fault description: HighPressure Switch Open
Potential cause and action: HighPressure switch trip. Try to Re-Check refrigerant charge, out-door fan operation, and finally coils for possible airflow restrictions.
Error code 32
Fault description: LowPressure Switch Open
Potential cause and action: LowPressure switch trip. Try to Re-Check refrigerant charge and indoor airflow
Error code 45
Fault description: Control Fault
Potential cause and action: Outdoor unit control board failure. Replacement needed
Error code 46
Fault description: Brown Out (230v)
Potential cause and action: Line voltage < 187volts for at least four seconds. Fan and compressor operation not permitted until voltage>190volts. Verify actual line voltage.
Error code 47
Fault description: No 230v at Unit
Potential cause and action: There is no 230volts at the contactor when the indoor unit is powered and cooling/ heating demand exists. Confirm the disconnect has been closed and the 230v wiring connected to the appliance.
Error code 53
Fault description: Outdoor Air Temp Sensor Fault
Potential cause and action: Outdoor air sensor out of range or not reading. Ohm out sensor and check wiring.
Error code 55
Fault description: Out-door Coil Sensor Fault
Potential cause and action: Coil sensor may not be reading or is out of range. Ohm out sensor and check wiring.
Error code 56
Fault description: Thermistors out-of-range
Potential cause and action: Improper relationship between the coil sensor & outdoor air sensor. Ohm out sensors and inspect wiring.
Error code 71
Fault description: low-stage thermal cut-out
Potential cause and action: Compressor action detected then disappeared while low-stage demand endures. Why? Internal compressor may be experiencing over-load trip or the start relay plus capacitor held in the circuit a bit long(where installed)
Error code 72
Fault description: High stage Thermal Cut-out
Potential cause and action: Compressor operation recognized then disappeared while highstage demand exists. Reasons? Internal compressor over-load trip/start relay plus capacitor held in the circuit too long(where installed)
Error code 73
Fault description: Contactor Shorted
Potential cause and action: Compressor voltage d_etected when demand for compressor action does not exist. Contactor could be stuck closed/there is, probably, some wiring error.
Error code 7
Fault description:
Potential cause and action:
Error code 74
Fault description: No 230V at Compressor (24ANA1 Only)
Potential cause and action: Compressor voltage not sensed when compressor should be starting. Contactor could be stuck closed/there is some wiring error.
Error code 75
Fault description: Low-stage Did Not Start (24ANA7 Only)
Potential cause and action: Specified start voltage at VR terminal was not achieved in low-stage. Start relay de-energized after one second.
Error code 76
Fault description: Low-stage didn’t start three (3) times (24ANA7 Only)
Potential cause and action: For 3 (three) low-stage consecutive starts, the stipulated start voltage (at VR terminal) wasn’t achieved&start relay was de-energized. Low-stage locked out for 30 minutes.
Error code 77
Fault description: High-stage failed to start(24ANA7 models only)
Potential cause and action: Specified start voltage (at VS terminal) not attained in high-stage. The start relay de-energized after one (1) second.
Error code 78
Fault description: High-stage failed to start 3 times (24ANA7 models only)
Potential cause and action: For three(3) consecutive high-stage starts, defined start voltage (at VS terminal) was not reached & start relay de-energized. High-stage locked out (for 30 minutes).
Error code 81
Fault description: Low-stage Thermal Lockout
Potential cause and action: Thermal cut-out happens in three(3) consecutive low/high-stage cycles. Low-stage locked out (for 4 hours) or until the 24volts power recycled.
Error code 82
Fault description: High-stage Thermal Lockout
Potential cause and action: Thermal cutout occurs in three consecutive high/low-stage cycles. High-stage locked out (for 4 hours) or until the 24v power recycled
Error code 83
Fault description: Low Pressure Lockout
Potential cause and action: Low pressure switch trip has occurred during 3 consecutive cycles. Unit operation locked out (for 4 hours) or until the 24v power recycled.
Error code 84
Fault description: High Pressure Lock-out
Potential cause and action: HighPressure switch trip has happened during 3(three) consecutive cycles. The unit operation lock_ed out (for 4 hours) or until the 24v power recycled.
Error code 85
Fault description: Low contactor open (24ANA7 model Only)
Potential cause and action: Compressor voltage not sensed when compressor should be starting. Low-stage Contactor could be stuck open/there is some wiring error.
Error code 87
Fault description: High Contactor Open (24ANA7 Only)
Potential cause and action: Compressor voltage not sensed when compressor should be starting. high-stage contactor could be stuck open/there is some wiring error.
Carrier infinity fault codes –Infinity 19VS 24VNA9 fault codes
Error code 16
Description: Communications Loss
Error code 25
Description: Invalid model
Error code 31
Description: HighPressure Switch Open
Reset time (minimum in minutes): 15
Error code 32
Description: Low Pressure Trip
Reset time (minimum in minutes): 15
Error code 45
Description: Control Fault
Error code 46
Description: Brownout Event
Reset time (minimum in minutes): 6
Error code 48
Description: Lost Inverter Communications
Reset time (minimum in minutes): 6
Error code 49
Description: 230VAC Dropout-Reset Event
Reset time (minimum in minutes): 6
Error code 52
Description: Discharge Temp Sensor issue
Error code 53
Description: Out_door Air Temp Sensor problem
Error code 54
Description: Suction Temp Sensor error
Error code 55
Description: Coil Temp Sensor problem
Error code 56
Description: OAT-OCT Thermistor is Out-of-Range
Error code 57
Description: Suction Pressure Sensor error
Reset time (minimum in minutes): 15
Error code 58
Description: Suction Thermistor Range issue
Error code 59
Description: Discharge Temperature Out-of-Range
Reset time (minimum in minutes): 15
Error code 61
Description: Fan Inverter Fault
Reset time (minimum in minutes): 6
Error code 62
Description: Fan Inverter Temp. High
Reset time (minimum in minutes): 6
Error code 63
Description: Fan Inverter Over Current -SPD Limiting
Reset time (minimum in minutes): 6
Error code 65
Description: DC Voltage Low-SPD Limiting
Reset time (minimum in minutes): 6
Error code 66
Description: Outdoor Fan has Dropped Out
Reset time (minimum in minutes): 6
Error code 67
Description: Stator Heater Fault
Reset time (minimum in minutes): 6
Error code 68
Description: 10 Minutes Stage 2 Warm-up Delay
Reset time (minimum in minutes): 10
Error code 69
Description: Internal Fault in Inverter/Compressor
Reset time (minimum in minutes): 15
Error code 71
Description: Compressor Dropped Out
Reset time (minimum in minutes): 6
Error code 72
Description: Suction Over Temperature. Event
Reset time (minimum in minutes): 15
Error code 74
Description: Discharge Temp Out-of-Range Lockout
Reset time (minimum in minutes): 2 hrs.
Error code 75
Description: Maximum Power Mode-Temp
Error code 76
Description: Fan Inverter Lockout
Reset time (minimum in minutes): 2 hrs.
Error code 77
Description: Max. Power Mode-Comp Current
Error code 79
Description: Compressor/Inverter Fault
Reset time (minimum in minutes): 15
Error code 82
Description: Suction Over Temp. Lock-out ckout
Reset time (minimum in minutes): 4 hrs.
Error code 83
Description: Low Pressure Lock-out (for 4 hours)
Reset time (minimum in minutes): 4 hrs.
Error code 84
Description: High Pressure Lock-out (for 4 hours)
Reset time (minimum in minutes): 4 hrs.
Error code 85
Description: Fan Inverter Temp. Lock-out
Reset time (minimum in minutes): 15
Error code 86
Description: Fan Inverter Current Lock-out
Reset time (minimum in minutes): 15
Error code 88
Description: Inverter Temp Lock-out
Reset time (minimum in minutes): 2 hrs.
Error code 89
Description: Compressor Inverter Overcurrent Lock-out
Reset time (minimum in minutes): 15
Error code 91
Description: Inverter VDC Out Over Voltage Event
Reset time (minimum in minutes): 15
Error code 92
Description: Inverter VDC Out Under Voltage Event
Reset time (minimum in minutes): 15
Error code 93
Description: 230VAC UnderVoltage Event
Reset time (minimum in minutes): 15
Error code 94
Description: 230VAC OverVoltage Event
Reset time (minimum in minutes): 15
Error code 95
Description: High Current Lockout
Reset time (minimum in minutes): 2 hrs.
Error code 96
Description: VDC UnderVoltage Lockout
Reset time (minimum in minutes): 2 hrs.
Error code 97
Description: VDC OverVoltage Lockout
Reset time (minimum in minutes): 2 hrs.
Error code 98
Description: High Torque Event
Reset time (minimum in minutes): 10
Error code 99
Description: High Torque Lockout
Reset time (minimum in minutes): 2 hrs.
Note: Short flashes are indicated by the first digit while long flashes are indicated by the second digit in the fault/status code
Carrier infinity furnace fault codes
Error code 12
Fault description: Blower On After Power Up
Potential cause and action: Occurs when call for heat satisfies during blower on delay.
Error code 13/14/15
Fault description: Limit Circuit Lockout
Potential cause and action: Auto reset in 3 hours
Error code 21
Fault description: Gas Heating Lockout
Potential cause and action: Attention needed as control will not auto reset.
Error code 22
Fault description: Abnormal Flame-Proving Signal
Error code 23
Fault description: Pressure Switch Did Not Open
Error code 24
Fault description: Secondary Voltage Fuse Open
Potential cause and action: May see this fault during quick power interruptions
Error code 25
Fault description: Model Selection Or Setup Error
Error code 31
Fault description: High-Heat Pressure Switch Or Relay Did Not Close Or Reopened
Error code 32
Fault description: Low-Heat Pressure Switch Did Not Close Or Reopened
Potential cause and action: This fault may show up in the fault history of condensing furnaces due to unprimed trap at start up, wind, or other factors temporarily affecting the vent system. It is not necessarily a system problem. In case troubleshooting doesn’t discover a fault, turn low heat rise on in furnace setup to enhance inducer air flow by 15%.
Error code 33
Fault description: Limit Circuit Fault
Error code 34
Fault description: Ignition Proving Failure
Carrier infinity fault code 41 -furnace
Fault description: Blower Motor Fault
Potential cause and action: 41 codes may show up in fault history, but if system is operating properly, this can be ignored
Error code 42
Fault description: Inducer Motor Fault (VS Inducers Only)
Error code 43
Fault description: Low-Heat Pressure Switch Open While High-Heat Pressure Switch Closed
Error code 45
Fault description: Control Circuitry Lockout
Carrier infinity fault codes -Final words
This carrier infinity fault codes troubleshooting list is only meant to be a guide and you should not use it blindly- apply your knowledge, experience, and common sense alongside the above guidelines.
This- and obeying your instincts as you perform the diagnostics– will go a long way in helping you find the trouble spot as soon as possible.
ALSO READ:
How to reset air conditioner thermostat – steps and useful tips .
Je possède depuis mai 2016 une Thermopompe centrale Infiniti Green spreed de 3 tonnes. Un code d’erreur est apparu ce matin sur mon thermostat ” System fault – 95 high – current – lockout”. Suivant les instruction par téléphone de mon fournisseur attitré Termic (vendeur), j’ai désactiver le breaker de courant de la thermopompe durant environ 10 minutes et je l’ai reparti. Le tout a bien fonctionné durant 1 heures environ et le message a réapparu de nouveau. Quelques minutes plus tard, le message 69-Inverter/co – Mpressor – internal fault est apparu. Quoi faire avec ça?
What is a fault 186 on infinity thermostat with zone control
Cheers
Brent
You have not listed any information as to how to fix Code 37 problems
My thermostat has fault code 189… not found
Hi. Did you find out about this code ?( 189) I have that one too
If you found a remedy, please share!
muy buena la información